Description
EchoPod DX10, a general purpose non-contact ultrasonic level transmitter that outputs frequency or voltage for small tanks 49.2" (1.25 m) or less. EchoPod enables flexible design applications for system integration or retrofit of floats, conductance and pressure sensors. Well suited for fluid handling and chemical feed applications integrating process or control automation of small tanks mounted on tools, skids or machines. The rugged PVDF enclosure is well suited for a wide range of corrosive, waste or slurry type media, and can be broadly selected for atmospheric day tank, process vessel or dispenser, pump lift station and waste dump applications. Level indication can be monitored via a local display or controlled through a PLC.
Advantages
Technical Specifications
Range:
49.2" (1.25m)
Accuracy:
0.125" (3mm)
Resolution:
0.019" (0.5mm)
Beam Width:
2" (5cm)
Dead band:
Supply voltage:
24 VDC (loop)
Consumption:
0.5W
Signal output:
0-5 V, 0-10 V. 976-2000 Hz
Frequency:
Sink current = 15 mA nominal
Fail-safety:
Full, empty, hold last
Configuration:
WebCal® (PC Windows®)USB 2.0
Temp. comp.:
Automatic over range
Process temp.:
F: 20° to 140°C:-35° to 60°
Ambient temp.:
F: -31° to 140°C: -7° to 60°
Pressure:
MWP = 30 PSI
Enclosure:
Type 6P, encapsulated, corrosion resistant & submersible
Encl. material:
Polycarbonate
Strain relief mat.:
Santoprene
Trans. material:
PVDF
Cable length:
48" (1.2m)
Cable jacket mat.:
Polyurethane
Process mount:
1" NPT (1" G)
Mount. gasket:
Viton®
Classification:
General purpose
Approval:
cFMus, CE